Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 14(19)2021 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-34639946

RESUMO

This study demonstrates a novel application of laser-induced graphene (LIG) as a reusable conductive particulate matter (PM) filter. Four types of LIG-based filters were fabricated based on the laser-induced pyrolysis of thin polyimide (PI) sheets, each pyrolyzed on either a single side or both sides, with or without densification. The LIG filters exhibited a high removal efficiency while maintaining minimal pressure drop compared to a commercial fiberglass filter. The densified LIG (dLIG) filters displayed a higher PM2.5 removal efficiency (>99.86%) than regular LIG filters. The dLIG filters also exhibited excellent durability when tested for washability by ultrasonication in tap water. After being cleaned and left to dry, the structures of the dLIG filters were well-maintained; their filtration efficiencies were also well-maintained (less than a 7% change in PM2.5 removal efficiency), and their resistances only marginally increased (less than a 7% increase after five uses). These results demonstrate the robustness and reusability of the dLIG filters and the accessibility of their cleaning (not requiring aggressive cleaning agents). These promising features will enable the application of LIG in economical, scalable, and high-performance air cleaning.

2.
Nanomaterials (Basel) ; 11(2)2021 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-33572253

RESUMO

Square-shaped or rectangular nanoparticles (NPs) of lanthanum oxide (LaOx) were synthesized and layered by convective self-assembly to demonstrate an analog memristive device in this study. Along with non-volatile analog memory effect, selection diode property could be co-existent without any implementation of heterogeneous multiple stacks with ~1 µm thick LaOx NPs layer. Current-voltage (I-V) behavior of the LaOx NPs resistive switching (RS) device has shown an evolved current level with memristive behavior and additional rectification functionality with threshold voltage. The concurrent memristor and diode type selector characteristics were examined with electrical stimuli or spikes for the duration of 10-50 ms pulse biases. The pulsed spike increased current levels at a read voltage of +0.2 V sequentially along with ±7 V biases, which have emulated neuromorphic operation of long-term potentiation (LTP). This study can open a new application of rare-earth LaOx NPs as a component of neuromorphic synaptic device.

3.
Sci Adv ; 6(28): eabb2891, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32923592

RESUMO

Despite various approaches to immunoassay and chromatography for monitoring cortisol concentrations, conventional methods require bulky external equipment, which limits their use as mobile health care systems. Here, we describe a human pilot trial of a soft, smart contact lens for real-time detection of the cortisol concentration in tears using a smartphone. A cortisol sensor formed using a graphene field-effect transistor can measure cortisol concentration with a detection limit of 10 pg/ml, which is low enough to detect the cortisol concentration in human tears. In addition, this soft contact lens only requires the integration of this cortisol sensor with transparent antennas and wireless communication circuits to make a smartphone the only device needed to operate the lens remotely without obstructing the wearer's view. Furthermore, in vivo tests using live rabbits and the human pilot experiment confirmed the good biocompatibility and reliability of this lens as a noninvasive, mobile health care solution.

4.
Biosens Bioelectron ; 159: 112186, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32364939

RESUMO

In this study, high electron mobility transistor (HEMT) device was used as an immuno biosensor to measure concentration of a stress hormone, cortisol, by using selective binding on cortisol monoclonal antibody (c-Mab). Also, the HEMT sensor was enhanced in its sensitivity through light illumination to generate photocurrent. The optical pumping could assist the biosensor to discriminate more detailed change, which could result in an increment of limit of detection (LOD) to 1.0 pM cortisol level. It was the lowest level of detection with semiconductor device-based cortisol biosensors and the enhancement of surface potential sensitivity was induced by laser light (532 nm). Output current amplificated by photocurrent was higher than dark original current at about 3.39% when gate voltage is applied with -3 V. Since the device could be applied to not only standard cortisol solution but also real human salivary sample, it is expected to apply for in vitro direct diagnosis of point-of-care test (POCT).


Assuntos
Compostos de Alumínio , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Gálio , Hidrocortisona/análise , Lasers , Transistores Eletrônicos , Compostos de Alumínio/química , Gálio/química , Humanos , Técnicas Analíticas Microfluídicas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...